CE Certificated Skz2050b-5-Argon Ar Gas Alarming Device Gas Leakage Detector Gas Leakage Test

CE Certificated Skz2050b-5-Argon Ar Gas Alarming Device Gas Leakage Detector Gas Leakage Test

Ce certificated SKZ2050B-5-Argon Ar gas alarming device gas leakage detector gas leakage test Ce certificated SKZ2050B-5
Basic Info
Model NO. SKZ2050B-5-Ar
After-sales Service 12 Months Warranty
Warranty 12 Months Warranty
Brand Skz
Customized Customized
Portable Portable
Certification CE
Gas Ar
Type Thermal Conductivity Gas Analyzer
Measure Range 0-10%,50%,100%,99.999%Vol
Resolution 0.01%Vol,0.001%Vol
Certificate Exia II CT4, IP66, CE
Response Time Less Than 10s
Transport Package Customed Foam Inner to Fixed The Detector, Aluminu
Specification 30*30*15cm
Trademark SKZ
Origin China
HS Code 9027100090
Production Capacity 50000PCS/Year
Product Description

CE Certificated Skz2050b-5-Argon Ar Gas Alarming Device Gas Leakage Detector Gas Leakage Test

Ce certificated SKZ2050B-5-Argon Ar gas alarming device gas leakage detector gas leakage test


Ce certificated SKZ2050B-5-Argon Ar gas alarming device gas leakage detector gas leakage test to measure Argon Ar gas with pump built-in.

Note: our product has different measuring ranges. If you are not sure which one you use or have any questions, please send me an inquiry directly, and I will solve your doubts.

If you think it is suitable, you can also choose to place the order directly. After we receive your order, we will ship it for you within 7-10 days or faster.
Introduction:
It is used for on-site gas concentration detection and alarm for excessive gas concentration. It can detect the concentration of various toxic and harmful flammable gases, and display the real-time concentration value and standard signal output on the spot.

Use imported brand gas sensors (Honeywell, Japan Nemoto, British CITY, British Alpha, British Dynament, Swiss Membrapor, etc.) gas sensors,

The main detection principles are: electrochemistry, infrared, catalytic combustion, thermal conductivity, PID photoion. It has the advantages of stable signal, high sensitivity and precision, and the flameproof wiring method is suitable for various dangerous places.

Features:
•Explosion-proof, anti-lightning, anti-static, reverse connection, anti-EMI, EMC electromagnetic interference, anti-pulse surge current impact.
• Comply with the latest national standards and obtain the CPA measuring instrument type approval certificate, explosion-proof certification and other qualifications.
•Three-wire system or four-wire system 4-20mA standard signal output, voltage output, 2 sets of relay switch values.
• It also has a standard bus system RS485 output (RTU format), optional integrated sound and light alarm.
• Optional with extra charge wired transmission, LAN, Internet, wireless transmission (2 kilometers, 5 kilometers, unlimited distance).
• The wireless transmission method can be 433, GPRS, WIFI, and other methods.
• The standard infrared remote control can be operated in dangerous situations without opening the cover, and the remote control distance is 15 meters, which is simple and practical
• Each unit can be switched to each other, automatically track the zero point to prevent drift, multi-level calibration.
• It can communicate with the computer, monitor the concentration of the field probe in real time through the upper computer on the computer, and store, analyze and print the data on the computer.

 

Technical Parameters:

Detection gasArgon Ar
Scope of detection0-10%,50%,100%,99.999%Vol
Resolution0.01%Vol,0.001%Vol
Detection principleThermal Conduction Principle
Sensor life2years
Detection accuracy≤±3%F.S
Linearity≤±2%
Repeatability≤±2%
uncertainty≤±2%
Recovery Time≤30S
Response timeT90≤20S
Signal outputBus system RS485 (RTU), three (four) wire system 4~20mA,
Optional: 0~20mA, 1~5V, 0~5V, 0~10V, wireless transmission, network transmission, SMS alarm.
Working environmentTemperature: -40ºC~+70ºC, humidity: ≤10~95%RH (normal)
Display method1.7-inch high-definition color screen display on site
Operating Voltage12~36VDC DC, the standard power supply of a single device is 24V, 1A or more than 1A DC regulated switching power supply
Power reference24V, 2.1A switching power supply can drive 40 toxic gas detectors, or 15 combustible and infrared gas detectors
Way of workingFixed installation, online detection, diffusion measurement; pipeline, flow, and pump-suction measurement are available.
Installation methodPipeline type and wall-mounted type. The working pressure of the pipeline type is ±30% of the atmospheric pressure, and the pressure needs to be reduced if it exceeds the range.
Alarm methodThe default is 1 channel, optional 2 passive contact (dry node) output, three-level alarm, and the alarm point can be set. On-site sound and light alarm (optional).
Connecting cables4~20mA three-core shielded cable, RS485 select four-core, single wire diameter ≥1.5mm when the distance exceeds 1000 m; the shielding layer is connected to the earth.
Protection levelIP65
Explosion-proof Flameproof, ExdIICT6Gb
Dimensions238×152×90mm(L×H×W) without alarm,
238×210×90mm(L×H×W) with alarm
weightwithout alarm1.38Kg with alarm1.6kg
Packing listManual, warranty card, packing box
Optional accessoriesIntegrated alarm lamp, power adapter, split alarm lamp, drying cylinder, flow-through connector, threaded welding seat, AC AC pump, DC brushless pump, vacuum pump, rain cover, water vapor filter, U-shaped buckle, 304/ 316/316L stainless steel gas chamber, 304/316/316L stainless steel housing
Optional functionWireless transmission, Hart protocol output, split detection

Customer show

CE Certificated Skz2050b-5-Argon Ar Gas Alarming Device Gas Leakage Detector Gas Leakage Test

CE Certificated Skz2050b-5-Argon Ar Gas Alarming Device Gas Leakage Detector Gas Leakage Test